wetzoeker

Regulation 47 Internationaal Verdrag voor de beveiliging van mensenlevens op zee, 1974

- ADDITIONAL REQUIREMENTS FOR PERIODICALLY UNATTENDED MACHINERY SPACES

1 Means shall be provided to detect and give alarms at an early stage in case of fires:

1. in boiler air supply casings and exhausts (uptakes); and

2. in scavenging air belts of propulsion machinery,

unless the Administration considers this to be unnecessary in a particular case.

2 Internal combustion engines of 2250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices.