wetzoeker

Regulation 62 Internationaal Verdrag van Torremolinos voor de beveiliging van vissersvaartuigen, 1977

- PERIODICALLY UNATTENDED MACHINERY SPACES

A safety system shall be provided so that serious malfunction in machinery or boiler operations, which presents an immediate danger, shall initiate the automatic shut-down of that part of the plant and an alarm shall be given. Shut-down of the propulsion system shall not be automatically activated except in cases which could lead to serious damage, complete breakdown, or explosion. Where arrangements for overriding the shut-down of the main propelling machinery are fitted these shall be such as to preclude inadvertent activation. Visual means shall be provided to show whether or not it has been activated.