wetzoeker

14b.2.12.6 — Emergency Escape Breathing Devices Regeling veiligheid zeeschepen

Emergency Escape Breathing Devices

Emergency escape breathing devices (EEBD’s) should comply with the Fire Safety Systems Code. At least one spare emergency escape breathing device should be kept onboard.

14B.2.12.6.1 All vessels should carry at least two EEBD’s within accommodation spaces, and at least two EEBD’s should be carried in each main vertical zone.

14B.2.12.6.2 On all vessels, within the machinery spaces, EEBD’s should be situated ready for use at easily visible locations, which can be reached quickly and easily at any time in the event of fire. The number and location should take into account the layout of the machinery space and the number of persons normally working in the space. The number and location of these devices should be indicated in the fire control plan.

Regeling
Regeling veiligheid zeeschepen
Soort
Ministeriële regeling
Geldend vanaf
01-07-2026
BWB-id
BWBR0017728
Versie
2026-07-01_0

In de hele regeling · Officiële tekst op wetten.overheid.nl