wetzoeker

14a.1 — General Regeling veiligheid zeeschepen

General

14A.1.1 Terms used in this section should have the same meaning as defined in SOLAS.

Table 14A.1.1 is a guide to the major requirements of this Section. The Table is intended as a quick reference to the requirements and is not to be used in isolation when designing the fire safety arrangements.

Table 14A.1.1

Passive fire protection (see 14A.2). | Category ‘A’ machinery spaces: ‘A-30’, (B-15 for short range yachts); Galleys: B-15 (for yachts not being Short Range Yachts)’.

Means of escape (see 14A.3): • Category ‘A’ machinery spaces. • Accommodation and other spaces | Two (2). Two (2).

Fixed fire detection system (see 14A.7). | • Fitted in machinery spaces. • Fitted in service spaces, control stations and accommodation spaces.

Automatic sprinkler system or equivalent | Fitted in yachts that do not meet restrictions on combustible materials (14A.2.3.6 & 14A.2.3.8).

Regeling
Regeling veiligheid zeeschepen
Soort
Ministeriële regeling
Geldend vanaf
01-07-2026
BWB-id
BWBR0017728
Versie
2026-07-01_0

In de hele regeling · Officiële tekst op wetten.overheid.nl